Rotary Seals

Walkersele M8

Description
This fluoroelastomer (FKM) material and method of construction are suitable for Walkerseles operating in high temperature environments. Walkersele M8 is a self-retaining seal for use in open housings.

Media compatibility
Excellent resistance to all lubricating oils, fuels, air, water and dilute acids.

Seal construction
Moulded in fluoroelastomer (FKM) with stainless steel band located in its back.

Maximum under-lip temperature
200°C constant: but note that under-lip temperature can often be substantially higher (eg, by 30°C) than fluid media temperature.  

Maximum surface speeds
20 m/s with Walkersele D6 and D8 designs.
18 m/s with Walkersele D7 design.

Back to top